Improper Installations

This system is not in compliance with EPA guidelines because: the exhaust point is not two feet above the opening (window), nor is it ten feet away from the entry way (door).

This system is not in compliance with EPA guidelines because: the exhaust point should be at minimum two feet above any opening (windows), and the horizontal pipe should be insulated to prevent freezing.

This system is not in compliance with EPA guidelines because the radon is being vented downwards. The exhaust point shall release at least ten feet off the ground vertically. The levels of radon coming out of the exhaust point is 500 to 1000 times greater than what is in the home, which makes it extremely dangerous to be close enough to breathe in the gas.

Examples of Bad System Installations